logo

High Power Low Noise EI96 Control Transformer Stable Efficient For Machine Tools

Place of Origin: China
Brand Name: CHIPSEN
Certification: UL/cUL Class B/F/H, VDE, CQC
Model Number: EI96
Minimum Order Quantity: 100
Price: $283.5-499.8/pieces
Delivery Time: 7-14 work days (Negotiable)
Payment Terms: T/T
Supply Ability: 10000pcs
Specifications
Highlight Features

EI96 Control Transformer

,

Low Noise Control Transformer

,

High Power control voltage transformer

Frequency:
50/60Hz
Input Voltage:
380V / 220 / 110V(Customized)
Enclouse:
NEMA 4X 304 SS
Standardscompliance:
UL, CSA
Core:
UI
Dielectric Strength:
1800V/min
Secondary:
24 With Fuse Clips
Cooling:
AN
Temperaturerise:
80°C
Insulation Resistance:
Three Phase >2MΩ
Terminal:
Screw Bolt
Primary Voltage:
440V
Application:
Control Circuits
Applications:
Machine Tools
Warranty:
5 Years
Product Description
High Power Low Noise EI96 Control Transformer

The EI96 is a larger open frame low frequency power and control transformer designed for voltage conversion, electrical isolation, and auxiliary power distribution in industrial equipment. Featuring insulated terminal blocks, a laminated EI core, and metal mounting base, this transformer provides stable and efficient performance for machine tools and industrial applications.

Industry Applications & Specifications
Industry & Application Common Input Requirements Common Output Requirements Key Parameters Customization Support
Machine Tool Equipment 220V-480V AC 24V-220V AC VA capacity, inrush performance, insulation Multiple input taps, output voltage, terminals
Industrial Automation 110V-480V AC 50/60Hz 12V-120V AC Regulation, efficiency, terminal layout Primary/secondary windings, thermal protection
Electrical Control Panels 220V-480V AC 24V-120V AC Wiring convenience, dielectric strength Terminal blocks, mounting holes, configurations
HVAC Equipment 120V-480V AC 12V-110V AC Continuous load, efficiency, noise Voltage ratio, bracket, fuse, thermostat
Energy & Power Systems 110V-480V AC 24V-220V AC Isolation, operating life, efficiency Multiple voltage taps, reinforced insulation
Customization Parameters
Parameter Typical Reference Customization Status
Core Type EI96 laminated silicon steel Customizable
Operating Frequency 50Hz, 60Hz, dual frequency Customizable
Primary Voltage 100V-480V AC Customizable
Secondary Voltage 6V-220V AC Customizable
Power Capacity 80VA-500VA Customizable
Insulation Class Class B, F, H Customizable
Terminal Type Screw, insulated, blade, lead wire Customizable
Product Construction
Construction Element Description
Magnetic Core EI96 laminated silicon steel for industrial frequency
Primary Winding Copper winding for single/dual/multiple input voltages
Secondary Winding Single/multiple copper windings for specified outputs
Terminal Blocks Insulated terminals for accessible equipment wiring
Mounting Base Metal bracket for chassis/cabinet installation
Thermal Protection Optional thermal fuse, thermostat, or protector
Key Features
  • EI96 laminated silicon steel core construction
  • Suitable for 50Hz and 60Hz power systems
  • Higher power capacity than smaller EI platforms
  • Stable voltage conversion and electrical isolation
  • Open frame construction for natural heat dissipation
  • Low audible noise design available
  • Single/dual and multiple voltage options
  • Insulated terminal blocks for convenient wiring
  • Secure metal base for chassis installation
  • Optional thermal protection and electrostatic shielding
Applications
  • Industrial machine tools and automation lines
  • Electrical control cabinets and motor control centers
  • HVAC control equipment and pump controllers
  • Programmable logic controller systems
  • Energy storage and renewable energy systems
  • Test and measurement instruments
  • Medical and laboratory equipment
  • Building automation and security systems
Quality Control

Chipsen establishes comprehensive manufacturing and inspection plans according to approved specifications. All production stages from incoming materials to final packaging are controlled through documented procedures.

Key Inspection Tests
  • Turns Ratio Test - Confirms designed voltage relationships
  • No Load & Full Load Voltage Tests - Verifies output performance
  • Insulation Resistance Test - Evaluates insulation integrity
  • Dielectric Strength Test - Verifies isolation capability
  • Temperature Rise Test - Confirms thermal performance
  • Efficiency Test - Evaluates transformer losses
  • Audible Noise Inspection - Detects abnormal vibration
Why Choose Chipsen
  • Customized voltage combinations and winding configurations
  • Drawing-based and sample-based replacement development
  • Custom power capacity, regulation, and efficiency design
  • Insulated terminal block and wiring configuration options
  • Optional thermal fuse, thermostat, and electrostatic shield
  • Prototype development and evaluation support
  • OEM and ODM customization with MOQ from one piece
  • Five-year warranty with extended options available
  • Electrical and mechanical testing per specifications
  • Material and production traceability
Frequently Asked Questions
What information is required for customization?

Provide input voltage, frequency, output requirements, duty cycle, ambient temperature, dimensions, mounting method, terminal arrangement, insulation requirements, and annual demand.

What power rating can an EI96 transformer provide?

Typically 80VA to 500VA, depending on core stack thickness, frequency, regulation, temperature rise, and construction.

Can it support multiple input voltages?

Yes, dual primary windings or multiple voltage taps can be designed for different supply voltages.

Is a one-piece sample available?

MOQ of one piece is available depending on material, tooling, complexity, and project review.

Are specifications guaranteed?

No, typical references are provided. Only values confirmed in approved documentation are guaranteed.

Related Products
Send An Inquiry