Custom ETD44 High Power High Frequency Transformer With 100 Watts Power Output And CE FCC

Place of Origin: China
Brand Name: CHIPSEN
Certification: UL/cUL Class B/F/H, VDE, CQC
Model Number: ETD44
Minimum Order Quantity: 1K
Price: $8.5-11.8/pieces
Delivery Time: 7-14 work days (Negotiable)
Payment Terms: T/T
Supply Ability: 10000pcs
Specifications
Highlight Features

ETD44 high power high frequency transformer

,

Custom high power high frequency transformer

,

100 Watts high frequency power transformer

Power Output:
100 Watts
Safety Features:
Overload Protection, Overheat Protection
Display:
Digital LCD
Compliance:
CE, FCC Certified
Voltage Input:
110V / 220V AC
Operating Temperature:
-10°C To 50°C
Control Interface:
Touchscreen And Remote Control
Warranty:
5 Years
Cooling Method:
Forced Air Cooling
Dimensions:
300mm X 200mm X 150mm
Weight:
4.5 Kg
Modulation Types:
AM, FM, Pulse
Frequency Range:
10 KHz - 30 MHz
Product Type:
High Frequency Generator
Product Description
ETD44 High Frequency Transformer
The ETD44 High Frequency Transformer is a customizable ferrite magnetic component designed for switch-mode power supplies, isolated control power, auxiliary power conversion, and high-frequency energy transfer.
Industry Applications & Specifications
Industry Typical Application Typical Power Inquiry Key Parameters Safety Focus
Industrial Automation and PLC PLC control power, HMI, I/O modules, industrial gateways 80 to 250 W Primary inductance, turns ratio, leakage inductance, DCR IEC 61010 or IEC 61558 requirements
Solar Inverter and Energy Storage Control board, gate driver, communication, BMS 100 to 300 W Core loss, copper loss, flux density, efficiency IEC 62109 requirements
EV Charger and Power Electronics Charging controller, communication module, gate driver 100 to 300 W Turns ratio, peak current, leakage inductance IEC 61851 requirements
Telecom and Network Equipment 48V bus converter, communication equipment 100 to 300 W Low DCR, controlled leakage inductance, efficiency IEC 62368-1 requirements
Medical Equipment Monitoring, diagnostic, treatment equipment 100 to 250 W Magnetizing inductance, capacitance, thermal margin IEC 60601-1 requirements
Product Construction
Construction Item Standard Reference or Available Option
Core Platform ETD44 ferrite core
Mounting Style Horizontal through-hole mounting
Pin Configuration Standard reference 9 plus 9 pins
Core Material Application-specific ferrite material
Insulation System Functional, basic, supplementary, double or reinforced insulation
Key Characteristics
  • High Efficiency: Optimized core material and winding arrangement reduce core loss and copper loss
  • Low Winding Resistance: Low-DCR options available with multi-strand wire, Litz wire, or foil
  • Controlled Leakage Inductance: Minimized or intentionally controlled according to converter topology
  • Low Noise Construction: Reduced audible noise through optimized mechanical design
  • Multiple Output Options: Support for single-output, multiple-output, center-tapped configurations
  • Flexible Insulation Design: Basic, reinforced, and customer-specific insulation constructions
Applications
  • Industrial automation control power supplies
  • PLC, HMI, and I/O module power
  • Solar inverter auxiliary power
  • Energy storage system control power
  • EV charging equipment
  • Telecom and network equipment
  • Medical equipment power supplies
  • Industrial LED drivers
  • Robotics equipment
Quality Control
Chipsen establishes application-specific quality and inspection plans including incoming material control, design review, in-process control, and comprehensive electrical testing.
  • Primary and secondary inductance testing
  • Turns ratio and polarity verification
  • Leakage inductance and DCR measurement
  • Dielectric strength and insulation resistance
  • Dimensional and visual inspection
Frequently Asked Questions
Q1: Is ETD44 a fixed power transformer model?
No. ETD44 defines the ferrite core and mechanical platform. Actual power capability depends on topology, input voltage, switching frequency, and thermal conditions.
Q2: What information is required for quotation?
Please provide input-voltage range, converter topology, switching frequency, output voltages/currents, power requirements, isolation voltage, and applicable safety requirements.
Q3: Can primary inductance and leakage inductance be customized?
Yes. Primary inductance tolerance and leakage-inductance targets can be defined according to the converter design requirements.
Q4: What is the MOQ?
The standard MOQ is 100 pieces. Prototype and production quantities can be discussed according to project requirements.
Q5: How long does quotation and sample production take?
Quotation target is within three days after complete technical requirements. Sample production targeted within seven days after specification confirmation.
Why Choose Chipsen
  • Application-Specific Customization: Developed around customer's actual circuit requirements
  • OEM and ODM Support: Complete customization of electrical and mechanical specifications
  • Engineering Collaboration: Technical review covering topology, thermal performance, and PCB installation
  • Flexible Prototype Support: Standard MOQ starts from 100 pieces
  • Responsive Project Handling: Quick quotation and sample turnaround
  • Warranty Support: Standard 5-year warranty, up to 20 years for qualified projects
Related Products
Send An Inquiry